Riskbedömning El — ELSÄK-FS och AFS 2023 för elentreprenörer Skip to content

Job Hazard Analysis for Electrical — create with RAMSagent

An electrical risk assessment documents and evaluates risks associated with electrical installation work according to HSE guidance on electrical safety, CDM 2015, and EN ISO 50110-1. It guides the choice of working method — de-energized, near live, or live — and the competency requirements for the workers involved.

RAMSagent links the risk assessment to competency levels, ensuring the right person is assigned the right task — from lighting service in residential properties to commissioning solar panel installations.

Typical risks for Job Hazard Analysis — Electrical

Risks, description, and applicable legislation
Risk Description Legal Severity
Electric Shock and Arc Flash Life-threatening risk when working on or near live parts — the main rule is to work de-energized according to HSE guidance; deviations require a special work permit from a qualified electrician. ELSÄK-FS (Elsäkerhet vid arbete) Critical
Falls from Height during Roof Installations Installation of solar panels, lighting, and antennas on roofs — requires a fall protection plan in accordance with CDM 2015, prioritizing collective protection. AFS 2023:11, 15 kap High
Fire from Incorrect Connections Cable fires in temporary installations on construction sites or in older buildings — requires correct cable sizing, overload protection, and residual current devices. AFS 2023:10 Medium
Work in Confined Spaces with Electrical Equipment Cable ducts, switchgear, and equipment rooms — combined risk of electric shock, oxygen deficiency, and rescue difficulties. AFS 2023:10, 5 kap High
ELSÄK-FS HSE Guidance on Electrical Safety
Main rule: work must be de-energized. Special work permits are required for deviations and are issued by a qualified electrician.
AFS 2023:11 Work Equipment and Personal Protective Equipment
Requirements for fall protection (Chapter 15) as well as PPE and insulating tools during electrical work.
AFS 2023:1 Fundamental Duties
Systematic health and safety work — requirements for the electrical contractor as the employer.

Frequently Asked Questions

Is ELSÄK-FS sufficient, or do I also need AFS 2023?
Both apply simultaneously. ELSÄK-FS regulates the electrical work itself, while AFS 2023 governs the overall work environment. RAMSagent automatically incorporates both.
How is a special work permit documented?
The risk assessment refers to the work permit as a separate document. The permit is issued by a qualified electrician and must be digitally signed by the worker before starting the work.