Arbetsberedning Måleri — lösningsmedel, ventilation & fall Saltar para conteúdo

Procedimento de trabalho seguro para Pintura — crie com RAMSagent

A method statement for painting describes surface preparation, priming, and topcoating both indoors and outdoors. It includes solvent exposure, ventilation requirements, fall protection for indoor high-rise work, and ergonomics for rolling on roofs.

RAMSagent links safety data sheets (SDS) to the method statement and alerts for products with high hygienic threshold values.

Riscos típicos para Procedimento de trabalho seguro — Pintura

Riscos, descrição e legislação aplicável
Risco Descrição Legislação Gravidade
Solvent Exposure Alkyd paints, varnishes, and cleaning agents contain hydrocarbons with hygienic threshold values. Hot work or spraying always requires fresh air masks. AFS 2018:1 Alta
Fire and Explosion Risk Solvent vapors form explosive mixtures at concentrations above the lower explosive limit (LEL). No spark generation; electrical equipment must be ATEX-rated in the risk area. AFS 2023:6 Alta
Falls Indoors from Scaffolding Step ladders and A-frames are the most common causes of falls in painting. Scaffolding or telescopic scaffolding should be used for work above 2 m. AFS 2023:11, 15 kap Alta
Load Ergonomics Rolling and painting above shoulder height puts strain on the shoulders and neck. Extension poles and adjustable scaffolding reduce the risk. AFS 2012:2 Média
AFS 2018:1 Hygienic Threshold Values
Lists threshold values for airborne contaminants — central to the choice of ventilation and respiratory protection.
AFS 2023:10 Chemical Workplace Risks
Requires risk assessment of chemical products, SDS, and hierarchy of controls.
AFS 2023:11 Work at Height
Regulates both internal and external scaffolding as well as personnel lifts.

Perguntas frequentes

Is standard ventilation sufficient indoors?
Often not sufficient for spray painting or large areas — HSE guidance requires mechanical ventilation that keeps air concentration below hygienic threshold values. RAMSagent calculates the flow based on room and product.
When is a flammable substances permit required?
When handling more than 500 liters of flammable liquid class 1–2b at the workplace, or when storing solvents in larger quantities. Contact the Fire and Rescue Service.

Modelo Word gratuito: procedimento de trabalho seguro

Indique o seu endereço de e-mail e aceite o tratamento de dados conforme a política abaixo. Receberá então o link para download do modelo.