Method Statement for Fire Protection — create with RAMSagent

A Site-Specific Safety Plan for passive fire protection describes firestopping of penetrations, application of fire-resistant paint, and installation of fire doors. It covers chemical exposure, hot work (welding, cutting), and roofing according to Canada Labour Code Part II (explosive atmosphere) and COHSR 5 (fire protection).

RAMSagent links to fire technical description (COHSR) and tracks certifications per fire section.

Typical risks for Method Statement — Fire Protection

Risks, description, and applicable legislation
Risk Description Legal Severity
Hot Work Welding, cutting, soldering require Hot Work certification, fire watch for 1 hour after completion, and fire extinguisher within 5 m. Canada Labour Code Part II; Hot Work Critical
Solvent-Based Fire-Resistant Paint Epoxy and intumescent paint contain isocyanates or solvents. Ventilation and respiratory protection according to SDS. Canada Labour Code Part II, 16 chap High
Roof Work at Penetrations Firestopping of roof penetrations (HVAC, electrical) occurs on the roof. Fall protection plan and roof-class scaffolding. Canada Labour Code Part II, 15 chap High
Silent Obligation If deficiencies in fire separations or incorrect escape routes are discovered during work, the client must be informed — silent awareness is not enough. Canada Labour Code Part II Medium
Canada Labour Code Part II Explosive Atmosphere (ATEX)
Requirements for hot work and solvent handling.
Canada Labour Code Part II Chemical Workplace Hazards
Regulates fire-resistant paint and solvents.
National Building Code of Canada (NBC) National Building Code chap 5
Fire rating of penetrations, fire compartment boundaries, and documentation.

Frequently Asked Questions

Is a Hot Work Certificate required?
Yes — a valid certificate is required for all hot work at temporary workplaces (renewed every 5 years). RAMSagent records the certificate's validity period in the Site-Specific Safety Plan.
Who is the fire watch?
A designated person with no other duties who monitors the work and for 1 hour after completion, with radio contact and firefighting equipment. Must be trained according to the Hot Work regulations.