Saltar al contenido

Procedimiento seguro para Aislamiento — crea con RAMSagent

Una planificación del trabajo para aislamiento describe cómo se aplica de manera segura la lana mineral, el poliestireno o el aislamiento proyectado. Incluye protección contra el polvo, protección de la piel, protección contra caídas en techos/ático y ventilación para productos de aislamiento a base de disolventes.

RAMSagent elige el nivel de protección adecuado según el material de aislamiento y el método de aplicación.

Riesgos habituales para Procedimiento seguro — Aislamiento

Riesgos, descripción y normativa aplicable
Riesgo Descripción Referencia legal Gravedad
Inhalation of Mineral Wool Dust Glass wool and rock wool can cause mechanical irritation in the respiratory tract. FFP2 respirators and full-body suits are required for prolonged work or enclosed environments. AFS 2023:10, 3 kap Medio
Skin Irritation Mineral wool fibers can cause itching and rashes. Long sleeves, gloves, and protective creams are necessary. Change work clothes before leaving the site. AFS 2023:10, 8 kap Medio
Fall Risk During Attic Insulation Loose insulation can conceal beams in uninsulated attics — a walkway or temporary protective roof over the insulation is required to prevent falls through the roof. AFS 2023:11, 15 kap Crítico
Isocyanates in Spray Insulation PU foam releases isocyanates during application — permits and medical monitoring are required. Air-fed respiratory protection and evacuation for 24 hours. AFS 2023:10, 16 kap; AFS 2005:6 Crítico
AFS 2023:10 Chemical Workplace Risks
Chapter 3 (dust exposure) and Chapter 16 (substances requiring permits such as isocyanates).
AFS 2023:11 Work at Height
Requirements for collective fall protection when working on roofs and attics over 2 meters.
AFS 2005:6 Medical Monitoring
Permits and medical monitoring are required when working with isocyanates (PU foam).

Preguntas frecuentes

Is a permit required for spray insulation with PU?
Yes — PU-based spray insulation releases isocyanates and requires a permit from the HSE and medical monitoring according to CDM 2015.
Is FFP2 sufficient against mineral wool?
FFP2 is adequate for short-term work in well-ventilated environments. In confined spaces, attics, or with larger quantities, FFP3 is recommended — RAMSagent flags this automatically.