Arbetsberedning Isolering — damm, hud & fall enligt AFS Saltar para conteúdo

Plano de Trabalho para Isolamento — crie com RAMSagent

A method statement for insulation describes how mineral wool, foam board, or spray insulation is applied safely. It includes dust protection, skin protection, fall protection when working on roofs/attics, and ventilation for solvent-based insulation products.

RAMSagent selects the appropriate level of protection based on insulation material and application method.

Riscos típicos para Plano de Trabalho — Isolamento

Riscos, descrição e legislação aplicável
Risco Descrição Legislação Gravidade
Inhalation of Mineral Wool Dust Glass wool and rock wool can cause mechanical irritation in the respiratory tract. FFP2 respirators and full-body suits are required for prolonged work or enclosed environments. AFS 2023:10, 3 kap Média
Skin Irritation Mineral wool fibers can cause itching and rashes. Long sleeves, gloves, and protective creams are necessary. Change work clothes before leaving the site. AFS 2023:10, 8 kap Média
Fall Risk During Attic Insulation Loose insulation can conceal beams in uninsulated attics — a walkway or temporary protective roof over the insulation is required to prevent falls through the roof. AFS 2023:11, 15 kap Crítica
Isocyanates in Spray Insulation PU foam releases isocyanates during application — permits and medical monitoring are required. Air-fed respiratory protection and evacuation for 24 hours. AFS 2023:10, 16 kap; AFS 2005:6 Crítica
AFS 2023:10 Chemical Workplace Risks
Chapter 3 (dust exposure) and Chapter 16 (substances requiring permits such as isocyanates).
AFS 2023:11 Work at Height
Requirements for collective fall protection when working on roofs and attics over 2 meters.
AFS 2005:6 Medical Monitoring
Permits and medical monitoring are required when working with isocyanates (PU foam).

Perguntas frequentes

Is a permit required for spray insulation with PU?
Yes — PU-based spray insulation releases isocyanates and requires a permit from the HSE and medical monitoring according to CDM 2015.
Is FFP2 sufficient against mineral wool?
FFP2 is adequate for short-term work in well-ventilated environments. In confined spaces, attics, or with larger quantities, FFP3 is recommended — RAMSagent flags this automatically.

Modelo Word gratuito: procedimento de trabalho seguro

Indique o seu endereço de e-mail e aceite o tratamento de dados conforme a política abaixo. Receberá então o link para download do modelo.