Evaluación de riesgos para Fachada — crea con RAMSagent
Una evaluación de riesgos para fachadas evalúa los riesgos del proyecto durante el montaje de andamios, la renovación o la nueva construcción de fachadas. Incluye protección contra caídas, influencia del viento, materiales que caen sobre el tráfico peatonal y ergonomía en trabajos en altura.
RAMSagent genera planes de andamios y protección contra caídas basados en la altura de la fachada, elección de materiales y proximidad al público.
Riesgos habituales para Evaluación de riesgos — Fachada
| Riesgo | Descripción | Referencia legal | Gravedad |
|---|---|---|---|
| Falling from Scaffold | Façade scaffolding over 2 m without complete guardrails poses the highest risk of fatal accidents on the project. Scaffold class, contractor certification, and inspection are required. | AFS 2023:11, 15 kap; AFS 2013:4 | Crítico |
| Falling Materials | Façade work over public traffic requires protective canopies, solid scaffolding, or closed passages. The risk assessment will size these requirements. | AFS 2023:13, 10 kap | Alto |
| Wind Impact | Sheet metal and façade panels are sensitive to wind — storms can throw materials over long distances. Work must stop when wind exceeds 10 m/s. | AFS 2013:4 | Alto |
| Ergonomics at Height | Prolonged work above shoulder height can cause strain injuries in the shoulders and neck. Platform height should be adjustable for each task. | AFS 2012:2 | Medio |
Normativa aplicable
- AFS 2023:1 HSE Guidance
- Systematic approach to health and safety management.
- AFS 2013:4 Scaffolding
- Scaffold classes, training, and inspection.
- AFS 2023:11 Work at Height Regulations
- Chapter 15 for construction sites.
Preguntas frecuentes
- Who inspects the scaffold?
- The scaffold must be inspected after assembly, after weather impacts, and at least once a week by a qualified person (HSE guidance). The inspection checklist is included in the risk assessment.
- What are the requirements for façade work over pedestrian traffic?
- Either closure (permission from local authority/police) or a protective canopy sized for falling materials. The Planning and Building Act imposes additional requirements.
Guías relacionadas