Подготовка работ по изоляции описывает, как безопасно наносить минеральную вату, пенопласт или распыляемую изоляцию. Она включает защиту от пыли, защиту кожи, защиту от падений на крыше/чердаке и вентиляцию для изоляционных продуктов на основе растворителей.
RAMSagent выбирает правильный уровень защиты в зависимости от изоляционного материала и метода нанесения.
Типичные риски: Технологическая карта — Теплоизоляция
| Риск | Описание | Норматив | Серьёзность |
|---|---|---|---|
| Inhalation of Mineral Wool Dust | Glass wool and rock wool can cause mechanical irritation in the respiratory tract. FFP2 respirators and full-body suits are required for prolonged work or enclosed environments. | AFS 2023:10, 3 kap | Средняя |
| Skin Irritation | Mineral wool fibers can cause itching and rashes. Long sleeves, gloves, and protective creams are necessary. Change work clothes before leaving the site. | AFS 2023:10, 8 kap | Средняя |
| Fall Risk During Attic Insulation | Loose insulation can conceal beams in uninsulated attics — a walkway or temporary protective roof over the insulation is required to prevent falls through the roof. | AFS 2023:11, 15 kap | Критическая |
| Isocyanates in Spray Insulation | PU foam releases isocyanates during application — permits and medical monitoring are required. Air-fed respiratory protection and evacuation for 24 hours. | AFS 2023:10, 16 kap; AFS 2005:6 | Критическая |
Применимые нормативы
- AFS 2023:10 Chemical Workplace Risks
- Chapter 3 (dust exposure) and Chapter 16 (substances requiring permits such as isocyanates).
- AFS 2023:11 Work at Height
- Requirements for collective fall protection when working on roofs and attics over 2 meters.
- AFS 2005:6 Medical Monitoring
- Permits and medical monitoring are required when working with isocyanates (PU foam).
Часто задаваемые вопросы
- Is a permit required for spray insulation with PU?
- Yes — PU-based spray insulation releases isocyanates and requires a permit from the HSE and medical monitoring according to CDM 2015.
- Is FFP2 sufficient against mineral wool?
- FFP2 is adequate for short-term work in well-ventilated environments. In confined spaces, attics, or with larger quantities, FFP3 is recommended — RAMSagent flags this automatically.